DIN Rail PWM-Driver

From InCircuit
Jump to: navigation, search
This product is End of Life
This product is End of Life


Contents

Hardware

DIN Rail PWM-Driver - 15 Chanel PWM-Driver Module

DIN Rail PWM-Driver


Features:

  • 15x PWM-Driver output
  • 8x Binary input for external switches
  • 1x RS485 via BUS connector
  • Numeric display for device address
  • Arbitrary number of modules mountable side by side
  • Easy connection of all modules with BUS connector
  • All modules can communicate via RS485
  • DIN-Rail enclosure: 6 pitch units (div)
  • Other DIN-Rail modules available
  • Input voltage: 24V DC
  • Tempearture range from -10°C to +70°C




Railbus Registers / Sub addresses

Communication is implemented via the DIN Rail BUS Protocol. Available are these registers:

Duty cycles:

SADR 31 - 8 7 - 0 values Read Write
0x11 0 Duty Cycle Channel 1 Percent (1-100) X X
0x12 0 Duty Cycle Channel 2 Percent (1-100) X X
0x13 0 Duty Cycle Channel 3 Percent (1-100) X X
0x14 0 Duty Cycle Channel 4 Percent (1-100) X X
0x15 0 Duty Cycle Channel 5 Percent (1-100) X X
0x21 0 Duty Cycle Channel 6 Percent (1-100) X X
0x22 0 Duty Cycle Channel 7 Percent (1-100) X X
0x23 0 Duty Cycle Channel 8 Percent (1-100) X X
0x24 0 Duty Cycle Channel 9 Percent (1-100) X X
0x25 0 Duty Cycle Channel 10 Percent (1-100) X X
0x31 0 Duty Cycle Channel 11 Percent (1-100) X X
0x32 0 Duty Cycle Channel 12 Percent (1-100) X X
0x33 0 Duty Cycle Channel 13 Percent (1-100) X X
0x34 0 Duty Cycle Channel 14 Percent (1-100) X X
0x35 0 Duty Cycle Channel 15 Percent (1-100) X X


Enable:

SADR 31 - 1 0 values Read Write
0x16 0 Enable Channel 1 On/Off (1 or 0) X X
0x17 0 Enable Channel 2 On/Off (1 or 0) X X
0x18 0 Enable Channel 3 On/Off (1 or 0) X X
0x19 0 Enable Channel 4 On/Off (1 or 0) X X
0x1A 0 Enable Channel 5 On/Off (1 or 0) X X
0x26 0 Enable Channel 6 On/Off (1 or 0) X X
0x27 0 Enable Channel 7 On/Off (1 or 0) X X
0x28 0 Enable Channel 8 On/Off (1 or 0) X X
0x29 0 Enable Channel 9 On/Off (1 or 0) X X
0x2A 0 Enable Channel 10 On/Off (1 or 0) X X
0x36 0 Enable Channel 11 On/Off (1 or 0) X X
0x37 0 Enable Channel 12 On/Off (1 or 0) X X
0x38 0 Enable Channel 13 On/Off (1 or 0) X X
0x39 0 Enable Channel 14 On/Off (1 or 0) X X
0x3A 0 Enable Channel 15 On/Off (1 or 0) X X


Per Group Settings:

SADR 31 - 8 7 - 0 values Read Write
0x1C 0 Duty Cycle Channel 1-5 Percent (1-100) - X
0x2C 0 Duty Cycle Channel 6-10 Percent (1-100) - X
0x3C 0 Duty Cycle Channel 11-15 Percent (1-100) - X
SADR 31 - 5 4 3 2 1 0 values Read Write
0x1D 0 Enable Channel 5 Enable Channel 4 Enable Channel 3 Enable Channel 2 Enable Channel 1 On/Off (1 or 0) X X
0x2D 0 Enable Channel 10 Enable Channel 9 Enable Channel 8 Enable Channel 7 Enable Channel 6 On/Off (1 or 0) X X
0x3D 0 Enable Channel 15 Enable Channel 14 Enable Channel 13 Enable Channel 12 Enable Channel 11 On/Off (1 or 0) X X


Global:

SADR 31 - 8 7 - 0 values Read Write
0xA0 0 Duty Cycle All Channels Percent (1-100) - X
SADR 31 - 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 values Read Write
0xA3 0 Enable

Channel 15

Enable

Channel 14

Enable

Channel 13

Enable

Channel 12

Enable

Channel 11

Enable

Channel 10

Enable

Channel 9

Enable

Channel 8

Enable

Channel 7

Enable

Channel 6

Enable

Channel 5

Enable

Channel 4

Enable

Channel 3

Enable

Channel 2

Enable

Channel 1

On/Off (1 or 0) per Channel X X
SADR 31 - 1 0 values Read Write
0xB0 0 Global Enable On/Off (1 or 0) X X
SADR 31 - 1 0 values Read Write
0xB5 0 Temporary Only yes or no (1 or 0) X X
SADR 31 - 8 7-0 values Read Write
0xBA 0 Full On Percent(1-100) X X
SADR 31 - 8 7-0 values Read Write
0xBA 0 Full On Percent(1-100) X X


SADR 31 - 8 7-0 values Read Write
0xC0 0 Max Duty Cycle Percent(1-100) X X
SADR 31 - 8 7-0 values Read Write
0xC1 0 Min Duty Cycle Percent(1-100) X X

Load defaults:

SADR 31 - 0 values Read Write
0xFD Load default values write (1F2E3D4C) - X

Common Railbus Registers:

Railbus Communication Settings
SADR 31 30 29 - 0 values Read Write
0xFE Suppress CRNL Suppress output reserved yes or no (1 or 0) X X
Device ID and Address
SADR 31 - 8 7 - 0 value Read Write
0xFF Device ID Device Address - X -
0xFF - Device Address new device address - X


Downloads