Skip to main content

ICfly-PowerFLARM-Adapter

ICfly-PowerFLARM-Adapter

The ICfly-PowerFLARM-Adapter connects a PowerFLARM traffic sensor to the ICfly bus. Traffic information from the FLARM then appears on the ICflyDisplay — alongside the artificial horizon and the engine data, without a second device in the panel.

Part number 902.174A002 — Shop

Connections​

SideConnectorPurpose
PowerFLARMfemale DE-15link to the traffic sensor
ICflyfemale DE-15ICfly bus to the display and other devices
Power5-pin connectorpower supply and optional systems such as an autopilot

Installation​

  1. Fit the adapter between the PowerFLARM and the ICfly bus.
  2. Connect the supply to the 5-pin connector.
  3. Enable the traffic display on the ICflyDisplay.

The adapter has nothing to configure: it passes on whatever the sensor delivers. If no traffic appears, the cause is the sensor or the wiring, not the adapter.

Siblings​

The same adapter is available for other traffic sensors:

Downloads​

See also​