ICT RS485 Radio Bridge

ICT RS485 Radio Bridge
ICT RS485 Radio Bridge from above
IP65 enclosure
Connections inside
Connections inside

The ICT RS485 Radio Bridge replaces a serial cable with a radio link. Two units form a transparent bridge: whatever enters the RS485 or RS232 interface on one side comes out unchanged on the other. Connected equipment needs no modification whatsoever — no drivers, no changed software.

A radio link always requires two units.

Part number 902.172 — Shop — Manual

Features​

  • Acknowledged transmission with automatic retries — no data loss, even during short radio disturbances
  • Buffer of 32 kB per direction with adjustable hold time
  • Serial formats 8N1, 8N2, 8E1, 8E2, 8O1, 8O2 — including Modbus RTU with frame mode
  • Baud rates from 1200 Bd to 1 MBd; selectable radio data rate between 4.8 and 250 kBd
  • Radio link always AES-128 encrypted, custom key can be set
  • Configuration via the Wi-Fi web interface (German/English) or over USB

Where it is used​

Between a controller or data logger on one side and inverters, sensors or other field devices on the other — wherever an RS485 line would be too long, too expensive, or impossible to lay.

Commissioning in six steps​

  1. Mount and connect — mount both radio bridges, fit the antennas and wire the serial lines to the terminals (RS485: A to A, B to B; or RS232).
  2. Power up — apply 8 to 24 V DC. The units start within a few seconds.
  3. Switch on Wi-Fi — press the button briefly. The blue LED lights up and the unit opens the network ICT-Funkbridge.
  4. Open the web interface — join that network and open http://192.168.42.1 in your browser.
  5. Configure — set the interface (port, baud rate, format) to match the connected equipment, then choose "Apply & save". Both bridges must carry the same radio settings; as delivered they already match.
  6. Check — the status card shows "partner reachable" with a signal level as soon as the other unit is in range and switched on. Then switch the Wi-Fi off again with the button.

Technical data​

PropertyValue
Supply8–24 V DC
InterfacesRS485 (2-wire, half duplex), RS232, USB (service)
Baud rates1200 Bd – 1 MBd
Serial formats8N1, 8N2, 8E1, 8E2, 8O1, 8O2
Radio frequency868.3 MHz (SRD band)
Radio data rates4.8 / 38.4 / 100 / 250 kBd
Transmit power+10 dBm / −0.5 dBm
Radio channels256
EncryptionAES-128, always active; custom key can be set
Buffer32 kB per direction
Antenna connectorRP-SMA
ConfigurationWi-Fi web interface (DE/EN), USB terminal
Protection classIP65
Dimensions / weight120 × 58 × 34 mm / 75 g
Operating temperature−40 °C to +85 °C
Dimensions (L × W × H)120 × 58 × 34 mm
Weight75 g
MaterialABS
Colourgrey

Radio approval: operation in the 868 MHz SRD band is subject to restrictions that depend on country and sub-band, such as duty cycle limits. Please check the requirements of your country of use, especially for applications with a permanently high data load.

Troubleshooting​

SymptomPossible cause / remedy
The web interface shows "no partner"The other unit has no power or is out of range; check the antenna. Do both units carry the same network ID, radio channel, radio data rate and key?
The link is up but no payload arrivesBaud rate and format matching the application? RS485 wires A and B swapped? The right port (RS485 or RS232) selected?
The Modbus master reports timeoutsIncrease the master's response timeout by the radio latency (typically +200 ms), switch on frame mode, use addressed operation

Complete manual​

Planning, configuration in detail, addressed operation, encryption, status indications, throughput and buffering are all covered in the ICT RS485 Radio Bridge manual — bilingual, with a switch at the top right.

See also​